Processor Options |
| Processor |
Two Quad-core AMD Opteron Processors only, (Model 2356 Rev F 2.3 GHz) |
|
| Cache |
128K L1, 512K L2 each core and 2MB L3 shared by all four cores. |
|
Main Memory |
| Memory Type |
DDR-2 675 MHz (PC3200) registered DIMMs with ECC (128 bit plus ECC databus) |
|
| Memory Capacity |
16 DDR2 DIMM slots (8 per processor)
64GB maximum with 2 CPUS and 4GB DIMMs, standard 32GB |
|
Hard Disk |
| Hard Disk Supported |
Forty-eight hot-swappable, 3.5" SATA II Disk |
|
| RAID Configurations |
SW RAID enabled by RAID-Z in Solaris ZFS for RAID 0, 1, 0+1, 5, and RAID z2 for RAID 6 |
|
Standard/Integrated Interfaces |
| Network |
Four 10/100/1000Base-T Ethernet ports, RJ45 connector |
|
| Network Management |
One dedicated 10/100Base-T Ethernet port, RJ45 connector |
|
| Serial |
One TIA/EIA-232-F asynchronous RJ45 connector |
|
| SATA |
Six 8-port SATA controllers, internal access only. |
|
| USB |
Four USB 2.0 ports (2 Front, 2 Rear) |
|
| Graphics |
ATI Rage XL video chip, VGA Video port |
|
| Expansion Bus |
Three internal MD2 Low Profile 64-bit PCI-express slots |
|
Software |
| Operating Environment |
Open Solaris, Solaris, RHEL, Suse Linux, Windows |
|
| Languages |
C/C++, FORTRAN, Java programming language, all other standard Sun-supported languages |
|
| Networking Software |
ONC, ONC+, NFS, WebNFS, TCP/IP, SunLink, OSI, MHS, IPX/SPX, SMB technologies, and XML |
|
| Management |
CLI (in-band and out-of-band), IPMI 2.0 (in-band and out-of-band), SNMP (out-of-band only) |
|
Power Supplies |
|
Dual redundant, hot-swappable power supply for 220V power supply, xoption of 3rd PSU for 110V with three PSU. |
|
| UL Maximum( AC Input) |
1800W |
|
| Power Supply Rating (DC output) |
1500W |
|
| Typical Power Consumption |
1200W, with 200CFM, max measured is 1200W |
|
Environment Limit |
| AC power Source Rating |
200-220VAC @ 10 Amps, 100V-110V with three PSUs |
|
| Operating Temperature/Humidity |
5 ºC to 32 ºC Altitude (operating) Up to 3048 m1
Altitude (nonoperating) Up to 12000 m |
|
| Nonoperating Temperature/Humidity |
-40 ºC to 65 ºC (-40 ºF to 149 ºF), up to 93% relative humidity, non-condensing, 38 ºC max wet bulb |
|
| Altitude (operating) |
Up to 4000 m, maximum ambient temperature is derated by 1
degree C per 300 m above 900 m |
|
| Altitude (nonoperating) |
Up to 12000 m |
|
Acoustic Noise Emissions |
|
Declared noise emissions in accordance with ISO 9296, A-weighted,operating and idling: |
|
| Measure & Environment |
|
|
| LwAd (1B = 10dB) |
7.5 B (per spec., actual is TBD)
8.5 B (per spec., actual is TBD) |
|
| LpAm bystander |
65dB (per spec., actual is TBD)
75dB (per spec., actual is TBD) |
|
Regulations |
|
Meets or exceeds the following requirements: |
|
| Safety |
IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences |
|
| RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.3.2, ICES-003 |
|
| Immunity |
EN55024,EN300-386:v1.3.2 |
|
| Certifications: Safety EMC |
cULus Mark, UL/Demko GS Mark, CE Mark, CCC, GOST R, S-Mark
CE Mark (93/68/EEC), Emissions and Immunity Class A Emissions Levels: FCC, VCCI, C-Tick, MIC, *CCC, *GOST R, *BSMI
* = Applicable at GA |
|
| Other |
Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive |
|
Dimensions and Weight |
| Chassis |
|
|
| Height |
175 mm (6.75 in.) (4RU) |
|
| Width |
445 mm (17 in.) 19" rack mountable |
|
| Depth |
736 mm (29 in.) |
|
| Weight |
88 kg ( 170lb.) maximum with rack kits |