|
Processor |
| Processor |
Up to two Dual-Core AMD Opteron processors, model 2214 HE or Quad-Core
AMD Opteron processors,model 23HF HE (embedded-class version) |
|
| Cache per Processor |
1MB Level 2 Cache per core |
|
Main Memory |
| Main Memory |
Eight DIMM slots (four DIMM slots per CPU socket), DDR2/667
registered ECC DIMMs (128-bit plus ECC databus), system maximum of 32
GB. Supports, 2GB and 4GB DIMMs |
|
System Architecture |
| System Architecture |
Three 8.0GB/s HyperTransport links per processor and 10.7GB/s access between each processor and memory |
|
Standard/Integration Interfaces |
| Network |
Four 10/100/1000 Mbps Ethernet |
|
| Network Management |
One 10/100 Mbps Ethernet port |
|
| Serial Management |
One TIA/EIA-232-F asynchronous RJ45 port |
|
| USB |
Two 2.0 USB ports (rear) |
|
| Expansion Bus |
Three full-height PCI-X slots for 64-bit 133 MHz, 2x full-length, 1x-half-length
One PCI-Express slot for MD2 low profile cards (support x1, x4 and x8 width cards) |
|
| SAS |
Four-Channel SAS Interface, internal access only |
|
| Video |
One VGA Video port (HD-15) |
|
| Alarms |
Four fail-safe, dry contact alarms (critical, major, minor and user) (DB-15) |
|
Mass Storage and Media |
| Internal Disk (Option 1) |
Up to two 146GB 2.5” 10K rpm SAS disks, providing a maximum capacity of 292 GB, internal Hardware RAID 1 (mirroring) and RAID 0 (striping) supported, internal DVD RW Drive |
|
| Internal Disk (Option 2) |
Up to four 146GB 2.5” 10K rpm SAS disks, providing a maximum capacity of 584 GB, internal Hardware RAID 1 (mirroring) and RAID 0 (striping) supported, no DVD |
|
Software |
| Operating System |
- Solaris support beginning with Solaris 10 11/06 Operating system, 64-bit
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- Windows Server 2003
Enterprise Infrastructure Software: Sun Java |
|
| Management |
ILOM Service Processor providing: DMTF CLP-based CLI over SSH, Web-based GUI over HTTPS/HTTP, IPMI 2.0, SMP v1, v2c, and v3, remote graphical access over Ethernet and remote storage over Ethernet. N1 System Manager support |
|
Power Supplies |
| Power Supplies |
Two redundant DC or AC hot-swappable power supplies |
|
| Maximum Power |
550 W |
|
Environment |
| DC Power |
-48VDC or -60VDC (12.7A at -48VDC, 10.2A at -60VDC) |
|
| AC Power |
100-240 VAC, 50-60 Hz (6.5A @ 100 to 120 VAC, 3.2A @ 200 to 240 VAC) |
|
| Temperature (operating) |
5°C to 40°C, (41°F to 104°F), Short Term -5°C to 55°C (23°F to 131°F) |
|
| Relative Humidity (operating) |
5% to 85% relative humidity, non-condensing |
|
| Short Term Humidity |
5% to 90% relative humidity, non-condensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air) |
|
| Altitude (operating) |
Up to 3000 meters (9,850 feet) @40°C |
|
| Temperature (non-operating) |
-40°C to 70°C (-40°F to 158°F) |
|
| Relative Humidity (non-operating) |
Up to 93% relative humidity non-condensing, 38°C (100.4°F) max wet bulb |
|
| Altitude (non-operating) |
Up to 12,000 meters (40,000 feet) |
|
| Declared Acoustics |
Operating/Idling Acoustic Noise 7.0B (LwAd, 1B=10dB) |
|
Dimensions and Weight |
| Height |
89 mm (3.5 inches) |
|
| Width |
442 mm (17.4 inches) including the bezel |
|
| Depth |
508 mm (20 inches) maximum depth |
|
| Weight |
35 lbs (fully configured without PCI cards) the two disk option
37.2 lbs fully configured without PCI cards) the four disk option |
|
| Enclosure |
Fits into standard 19-inch rack wide rack. Rack kit included: 19-inch 4-post |
|
| Additional Rack Kits Available |
19-inch 2-post, 23-inch 2-post, 600mm x 600mm and 19-inch 4-post slide adjustable |
|
Regulations |
|
Meets or exceeds the following requirements |
|
| Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, and CFR21 part 1040 |
|
| Ergonomics |
EK1-ITB-2000 |
|
| RFI/EMC |
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A, EN61000-3-2, EN61000-3-3 |
|
| Immunity |
EN55024/CISPR24 |
|
| Telecommunications |
EN300-386, Telecordia SR 3580 NEBS Level 3 Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, MIC, UL/cUL,
UL/DEMKO/GS, UL/S-mark, BSMI, CCC |
|
| ETSI |
ETSI: EN 300 019-2-1,2,3, Class 1.2, 2.3, 3.1E
- Except -5ºC cold start
- Except condensing humidity
- Except rain
|
|
| Seismic |
GR-63-CORE requirements for earthquake zone 4 |
|
| Other |
Restriction of Hazardous Substances (RoHS) labeled, per WEEE (Waste Electrical and Electronics Equipment) directive (2002/95/EC) |