Architecture |
| Processor |
Up to eight core 1.2-GHz UltraSPARC T2 Plus processors; two processor per system, maximum 128 threads |
|
| Main Memory |
Up to 32 FB-DIMM slots. Up to 128 GB memory (up to 256 GB memory when 8GB DIMMs are available) |
|
Standard/Integration Interfaces |
| Network |
Four 10/100/1000 Mbps Ethernet; up to 2x optional 10 GbE XAUI connections;one RJ-45 serial management port; one 10/100 Mbps Ethernet network management port; one DB-9 serial port |
|
| Expansion bus |
10 PCI slots: 8 PCIe (6x PCI-Express slots for MD2 low profile cards ;
2x PCI-Express slots for full-height, full-length cards ) and 2 PCI-X slots (133MHz, 3.3V, FL/FH) |
|
| USB |
Four 2.0 USB ports |
|
| Virtualization |
Integrated, open-source, no-cost virtualization technology provides the flexibility and power of 128 virtual systems in a single server |
|
| Management |
Integrated Lights Out Manager |
|
| Mass Storage and Media |
Up to twelve 146 GB SAS disk drives, depending on configuration
One slimline DVD R/W drive |
|
Software |
| Operating system |
Support Solaris OS beginning with Solaris 10 OS 5/08 with patches 138312-01 and 125952-17 |
|
| Virtualization |
Integrated, open-source, no-cost virtualization technology provides the flexibility and power of 128 virtual systems in a single server |
|
Power Supplies |
| Power Supplies |
Four 2+2 redundant, AC or DC hot-swappable
650 W power supply units |
|
Environment |
| Operating Temperature |
5° C to 40° C (41° F to 104° F), short-term -5° C to 55° C (23° F to 131° F) |
|
| Nonoperating Temperature |
-40° C to 70° C (-40° F to 158° F) |
|
| Operating Relative Humidity |
5–85%, noncondensing |
|
| Short-Term Relative Humidity |
5–90%,
noncondensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lbs. dry air) |
|
| Nonoperating Relative Humidity |
Up to 93%, noncondensing, 40° C (104° F) |
|
| Operating Altitude |
Up to 3,000m (9,850 ft.) at 40° C |
|
| Nonoperating Altitude |
Up to 12,000m (40,000 ft.) |
|
| DC Power |
-48 V DC or -60 V DC |
|
| AC Power |
100–240 V AC, 50–60 Hz |
|
| Declared Acoustics |
Operating/idling 7.2 B (LwAd, 1 B = 10 dB) |
|
| ETSI |
EN300019-2-1,2,3, Class 1.2, 2.3, 3.1E
(except condensing humidity and rain) |
|
| NEBS |
NEBS Level 3 certified by Telcordia |
|
| Seismic |
GR-63-CORE requirements for
Earthquake Zone 4 |
|
Dimensions and Weight |
| Height |
174.2mm (6.86 in.) |
|
| Width (including bezel) |
445mm (17.5 in.) |
|
| Depth (max., to PSU handles) |
530mm (20.87 in.) |
|
| Depth (max., to rear I/O) |
505mm (19.88 in.) |
|
| Weight (fully loaded without PCI cards) |
33 kg (72.6 lbs.) |
|
Regulations |
| Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB
Scheme with all national differences, IEC825-1, 2, and CFR21 part 1040 |
|
| RFI/EMC |
EN55022/CISPR22 Class A, FCC CFR47 Part 15
Class A |
|
| Immunity |
EN55024/CISPR24, EN61000-3-2, EN61000-3-3 |
|
| Telecommunications |
EN300-386 |
|
| Regulatory Markings |
CE, FCC, ICES-003, C‑Tick, VCCI, GOST-R, MIC, UL/cUL, S-Mark, BSMI, CCC |
|
| Other |
Restriction of Hazardous Substances (RoHS) labeled, per WEEE (Waste Electrical and Electronics Equipment) Directive (2002/95/EC) |