Architecture |
| Processor Options |
Single-socket support for the Sun UltraSPARC T2 processor, with processor options for six or eight cores and eight threads per core |
|
| Main Memory |
Eight FB-DIMM memory sockets over four direct-to-CPU controllers and 8 channels; dedicated CF-2 slot for high-capacity flash memory — 8 GB and 16 GB options |
|
Standard/Integration Interfaces |
| Network |
Eight Gigabit Ethernet channels: two channels for base fabric (1 G – PICMG 3.0), two channels for extended fabric (10 G – PICMG 3.1, Option 9), three channels for Zone 3 (ARTM implementation-specific), one channel for front panel (1 G), one RS-232 serial port routed to the front and rear, two USB ports routed to the front panel |
|
| I/O Interfaces |
One ARTM I/O slot with management and hot-swap support |
|
Software |
| Operating System |
Solaris 10 Operating System |
|
| Data Plane Software |
Sun Netra Data Plane Software Suite |
|
| Management Software |
Sun Netra ATCA System Management |
|
| High-Availability Software |
Sun Netra HA Suite 3.0 |
|
Dimensions |
|
Single-slot ATCA (PICMG 3.0) |
|
| Height (8 RU) |
322.25mm |
|
| Depth |
280mm |
|
| Width |
30mm |
|
Environment |
| Operating Temperature |
5° C to 40° C (41° F to 104° F) 5–85% relative humidity, noncondensing short term; -5° C to 55° C (23° F to 131° F) 5–90% relative humidity, noncondensing, but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lb. dry air) |
|
| Nonoperating Temperature |
-40° C to 70° C (-40° F to 158° F), up to 93% relative humidity, noncondensing, 38° C (100.4° F) max. wet bulb |
|
| Acoustic Noise |
Declared noise emissions in accordance with ISO 9296: 7.0 B (operating and idling) |
|
| Cooling |
Available upon request |
|
| Seismic |
Meets GR-63-CORE requirements for earthquake risk, Zone 4 |
|
| Measured Power |
8C/16GB memory, no ARTM 200W |
|
Safety and Ergonomics |
|
cULus 60950, CSA C22.2 No. 60950, CB
Scheme-IEC 60950 with all national
differences, EN60950 (CE), GOST-R |
|
| Regulatory Compliance |
Class A FCC, CE,
VCCI, BSMI, C-Tick, MIC, GOST, S-MARK |
|
| Telecom Environment Certification |
Telcordia SR 3580, NEBS Level 3 |