Sun Fire T5120 Server
Active TabTech Specs
 

Specifications


Key Specifications

  • Chip Multithreading Technology (CMT) UltraSPARC T2 processor
  • Up to 64 simultaneous threads of execution
  • Up to 128 GB of memory
  • Common Integrated Lights Out Management (ILOM)
  • Solaris 10 Operating System and Linux
Processor
Processor 4, 6, and 8 core 1.2 GHz or 8 core 1.4 GHz UltraSPARC T2 processors; one processor per system, maximum 64 threads

Architecture SPARC V9 architecture, ECC protected

Cache per processor 4 MB integrated L2

Other key features
  • Under 95 W (nominal), and fewer than 2 W per thread
  • Dual, multithreaded, 10 Gb Ethernet and PCIe integrated onto chip
  • Eight floating-point units
  • Onboard cryptography supporting 10 embedded security industry-standard ciphers including: DES, 3DES, AES, RC4, SHA1, SHA256, MD5, RSA to 2048 key, ECC, CRC32
Main Memory
Main Memory Sixteen FB-DIMM slots, system maximum of 128 GB; support for 1 GB, 2 GB, 4 GB, and 8 GB DIMMs; minimum of 4 GB (4x 1 GB)
Standard/Integration Interfaces
Network
  • Four 10/100/1000 Mbps Ethernet
  • Up to 2 x optional 10GbE XAUI connections

Expansion bus 1x 8 lane PCI-E and 2x 4 lane PCI-E OR XAUI

USB Four 2.0 USB ports
Mass Storage and Media
Internal disk
  • Up to eight 73-GB, 146-GB, or 300-GB 2.5" SAS disks
  • Internal hardware RAID 0 (striping) and RAID 1 (mirroring) supported

Internal DVD One slimline CD-RW/DVD-RW
Software
Operating system
  • Solaris 10 8/07 OS and Solaris 10 10/08 OS
  • Ubuntu Linux distribution certified

Preloaded software
  • Solaris 10 10/08
  • Logical Domains Manager 1.0.3
  • Logical Domains MIB 1.0.1
  • Sun Studio 12
  • CMT Developer Tools Version 1.0
Power Supply
Power Supply Two hot-swappable AC 720 W "Climate Saver" power supply units (PSUs) providing N+1 redundancy come standard. Also available is a DC 660 W power supply unit.
Environment
Operating Temperature
  • Sea level to 2953 ft. (900m): 5° C to 35° C (41° F to 95° F)
  • Above 2953 ft (900m): Decrease the maximum allowable temperature by 1° C/300 m (1.6°F/1,000 ft)
  • IEC 60068-2-1 Test Ad, and 60068-2-2 Test Bd

Nonoperating Temperature -40° to 65° C (-40°F to 149°F); IEC 60068-2-1 Test Ab and 60068-2-2 Test Bb

Relative Humidity 10 to 90 percent RH, 27° C maximum wet bulb (noncondensing); IEC 60068-2-56 Test Cb

Nonoperating Relative Humidity 93 percent RH, 35° C maximum wet bulb (noncondensing); IEC 60068-2-56 Test Cb

Altitude 3,000m (10,000 feet); IEC 60068-2-13 Test M, and 60068-2-41Test Z/BM

Nonoperating Altitude 12,000m (40,000 feet); IEC 60068-2-13 Test M

Declared Acoustics
  • Operating/idling acoustic noise 7.0B (LwAd, 1B=10 dB)
  • Operating/idling acoustic noise 59 dB (LpAm, bystander positions)
Regulations
Meets or exceeds the following requirements:

Safety UL/CSA-60950-1, EN60950-1,IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336, GB4943

Ergonomics EK1-ITB-2000

RFI/EMC EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3

Immunity EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11

Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/DEMKOLVD, UL/S-mark, CCC
Dimensions and Weight
Height 44 mm (1.746 inches); one rack unit

Width 425 mm (16.75 inches)

Depth 714 mm (28.125 inches)

Weight Approximately 18 kg (40 lb)