Sun Blade 6000 Chassis |
| Form Factor |
10 Rack units high, (10U), holding up to ten server modules per chassis. Up to 4 Sun Blade 6000 Chassis are supported per 42U rack. |
|
| I/O Interfaces |
The Sun Blade 6000 midplane supports the following protocols: PCI Express, Gigabit Ethernet and SAS. Each server module has a direct connection to two PCIe ExpressModules for discrete I/O connectivity and two PCIe Network Express Modules for aggregate I/O connectivity. |
|
I/O Modules |
| ExpressModules |
Up to 20 ExpressModules per Sun Blade 6000 Chassis
- Sun StorageTek Dual 4Gb Fibre Channel Dual GbE ExpressModule HBA, Emulex
- Sun StorageTek Dual 4Gb Fibre Channel Dual GbE ExpressModule HBA, QLogic
- Sun StorageTek 4Gb Fibre Channel Dual-port ExpressModule HBA, Emulex
- Sun StorageTek 4Gb Fibre Channel Dual-port ExpressModule HBA, QLogic
- Sun StorageTek SAS HBA ExpressModule HBA
- Gigabit Ethernet Dual-port ExpressModule - Copper (Intel® 82571EB GbE Controller-based)
- Gigabit Ethernet Dual-port ExpressModule - Fiber (Intel® 82571EB GbE Controller-based)
- x4 Quad GbE ExpressModules (Intel® GbE Controller-based)
- Sun MT Quad GbE x8 ExpressModule (Sun Neptune)
- 4x InfiniBand Dual-port ExpressModule (Mellanox MT25208 InfiniHost III Ex Controller-based)
- Sun Dual-port DDR IB Host Channel Adapter ExpressModule (Mellanox ConnectX based)
- 10 Gigabit Ethernet (Fiber) Dual-port ExpressModule (Sun Neptune)
- EMx8 Host Express Module (Magma)
|
|
| PCIe Network Express Modules |
Up to 2 per Sun Blade 6000 Chassis
- Gigabit Ethernet 10-Port Passthru PCIe NEM
- Multi-Fabric NEM with Gigabit Ethernet 10-Port Passthru and SAS Expander
- Multi-Fabric NEM with Gigabit Ethernet 10-Port Passthru, 10 Gigabit Ethernet 10-Port Passthru and SAS Expander
|
|
Manageability |
| Chassis Monitoring Module (CMM) |
Chassis Monitoring Module (CMM):
- Enables direct connection to the Service Processor on each Blade Server
- Reduces cabling by providing a single management connection to the chassis
- Ensures complete lights-out manageability of the whole chassis
- Provides an optional aggregate point for monitoring of chassis fans, power supplies with its own Sun Integrated Lights Out Management (ILOM) module
|
|
Environment |
| Operating temperature |
5°C to 32°C ( 41°F to 90°F) |
|
| Nonoperating temperature |
-40°C to 65°C (-40°F to 149°F) |
|
| Operating optimum ambient temperature |
22°C (71.6 °F) |
|
| Operating Relative Humidity |
10 to 90 percent RH, noncondensing, 27°C max. wet bulb |
|
| Nonoperating Relative Humidity |
5 to 93 percent RH, noncondensing, 38°C max. wet bulb |
|
| Operating altitude |
Up to 3,048m (10,000 ft.), maximum ambient temperature is derated by 1°C per 300m
(984 ft.) above 900m (2,953 ft.) |
|
| Nonoperating altitude |
Up to 12,000m (39,370 ft.) |
|
| Operating Sine Vibration |
Z (vertical) axis: 0.15G
X/Y axis: 0.10G
5 to 500 Hz sine |
|
| Nonoperating Sine Vibration |
Z (vertical) axis: 0.50G
X/Y axis: 0.25G
5 to 500 Hz sine |
|
| Shock |
3Gs, 11msec, half sine
(rackmounted enclosure) |
|
| Acoustics |
LwAd (1 B=10 dB) 8.6 B at or below
25°C, 9.2 B at maximum ambient |
|
AC Power |
| Power |
Power (1+1) high-efficiency, hot-swappable, load-sharing, load-balancing power
supplies |
|
| Power Supply |
1+1 PSU rating: 5600 W each power supply module (two 2800W cores) |
|
| Voltage |
200 to 240 VAC |
|
| Frequency |
50 to 60 Hz |
|
| Current |
16A per power supply input, total four AC inputs (two per power supply module) |
|
| AC input connection |
Americas Domestic - NEMA L6-20P to IEC320-C19
International - IEC309 250V, 3A, 3 Pin to IEC320-C19 |
|
Regulations (meets or exceeds the following requirements) |
| Product Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences, IEC825-1, 2, CFR21 part 1040, CNS14336, GB 4943 |
|
| RFI/EMI (Class A) |
EN55022, 47 CFR 15B, ICES-003, VCCI, AS/NZ 3548, CNS 13438, KSC 5858, GB 9254, EN61000-3-2, GB 17625.1, EN61000-3-3, EN300-386: v1.3.3 |
|
| Immunity |
EN55024, EN300-386: v1.3.3 |
|
Certifications |
| Product Safety |
cULus Mark, UL/Demko LVD, CE Mark (2006/95/EC), GOST R, BSMI |
|
| RFI/EMI (Class A) |
CE Mark (89/336/EEC), FCC, ICES-003, VCCI, C-Tick, MIC, GOST R, BSMI |
|
| Immunity |
CE Mark (89/336/EEC), MIC, GOST R |
|
| Other |
Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive, China RoHS Mark |
|
Chassis and Components Physical Specifications |
| Chassis height |
17.25 inches (438.15 mm) |
|
| Chassis depth |
27.25 inches (692.15 mm) |
|
| Chassis width |
17.50 inches (444.50 mm) |
|
| Chassis weight of a fully configured system |
350 lb (159 kg) |
|
| Chassis weight of an empty system (No fillers) |
78.7 lb (35.7 kg) |
|
| Subassembly weights |
- Power Supply Module: 21.38 lb (9.70 kg)
- Network Express Module: 3.85 lb (1.75 kg)
- PCIe ExpressModule: 0.90 lb (0.41 kg)
- Rear Fan Module: 2.31 lb (1.04 kg)
- Chassis Monitoring Module: 1.15 lb (0.52 kg)
- Front Fan Module: 1.95 lb (0 .88 kg)